Error P0622 on Renault все модели
Generator Field/F Terminal Circuit
Code
P0622
Vehicle
Renault все модели
Category
Powertrain
Severity
🔴 HighSymptoms
- Check Engine Light and Battery Light Come On
- Battery not charging or charging at maximum voltage
- Rapid battery drain
- Battery overheating due to constant recharging
- Electronics malfunction due to unstable voltage
Causes
- Open or short circuit in the field winding circuit
- Faulty generator voltage regulator
- Broken wire terminal F between the generator and the computer
- Oxidation of the generator connector
- Internal malfunction of the generator field winding
How to Fix
- Measure the charging voltage with the engine running (normal 13.8–14.4 V)
- Check the terminal F wire from the generator to the ECU for open and short circuits.
- Measure the resistance of the field winding (the norm is 2–5 Ohms depending on the brand)
- Check the voltage regulator - measure the control signal at terminal F
- If the winding breaks, replace the generator or rewind the winding
- If the generator is working, ECU diagnostics
FAQ
Как проверить обмотку возбуждения генератора?
Отсоедините разъём генератора и измерьте сопротивление между клеммой F и корпусом. Норма — 2–5 Ом (зависит от модели). Бесконечность означает обрыв, близко к нулю — замыкание.
Чем отличается P0622 от P0625 и P0626?
P0622 — общая ошибка цепи поля генератора. P0625 — низкое напряжение в этой цепи. P0626 — высокое напряжение. P0622 может предшествовать появлению P0625 или P0626.