OBD Guide

P0EB9

A/C Compressor Motor Phase W Current Sensor Circuit Low

Severity
⚠️ Medium
Can you drive?
Yes, but get it checked soon
Approx. repair cost
$28–89 (est.)

Symptoms

  • The air conditioner does not work or does not work correctly
  • Noticeable reduction in cooling efficiency
  • The air conditioning indicator is flashing
  • Increased noise from the compressor
  • Other compressor electrical fault codes may be present.

Causes

  • Open or short circuit in the phase W current sensor circuit
  • Faulty phase W current sensor
  • Problems with connectors or contact corrosion
  • Malfunction of the air conditioning compressor control module
  • Damage to the wiring harness near the compressor

How to Fix

  1. Check the continuity and voltage in the phase W sensor circuit
  2. Inspect connectors and contacts for damage and corrosion
  3. Test the phase W current sensor with a multimeter
  4. If necessary, replace the current sensor or repair the wiring
  5. Check the operation of the compressor control module

Related codes

Error P0EB9 by Vehicle Brand